Evaluation

Certifications

Identification

Référence :
QB09
Intitulé :
Sewerage
Normes applicables :
Non applicable

Caractéristiques certifiées

  • Sewerage-Drain-networks

    • Vicat (> 79 ° C)
    • Tensile strength (> 20MPa)
    • Dimensional characteristics *
    • Mechanical characteristics (ring stiffness min> 4kN / m2 *), creep <2.5)
    • Impacts (TIR <10%)
    • Heat reversion (<5%)
    • Tightness of the assemblies of non-perforated tubes (No leaks according to standard NF EN 1053).
  • Small wastewater treatment systems

    • Dimensional characteristics
    • Mechanical characteristics in accordance with the requirements of the Technical Assessment
    • Tightness
    • “on site” purification performance (OBD, SS, OCD, NH4)
  • Rainwater treatment

    • Dimensional characteristics
    • Mechanical characteristics
    • Tightness
  • Water storage device

    • Surface weight
    • Armor
    • Thread
    • Grip
    • Tensile strength ( longitudinal direction / transverse direction)
    • Elongation at break ( longitudinal direction / transverse direction)
    • Resistance to tearing initiated ( longitudinal direction / transverse direction)
    • Dimensional characteristics
    • Tensile strength of welds
    • Static Puncture resistance
    • Resistance to chemical agents and UV
    • Tightness of unperforated pipe assemblies.
  • Drain networks (peripheral drainage to buildings)

    • Vicat> 75 ° C (if PVC)
    • MFR and OIT if PP / PE
    • Tests on the fiber coating (textile or geotextile)
    • Mechanical resistance tensile, compression)
    • Long-term mechanical behavior
    • Dimensional characteristics
    • Mechanical characteristics (ring stiffness, creep)
    • Impact
    • Static Puncture resistance
    • Slot / perforation widths
  • Drain networks (drainage of road works)

    • Vicat> 75 ° C (if PVC)
    • MFR and OIT if PP / PE
    • Tests on the fiber coating (textile or geotextile)
    • Mechanical resistance (tensile, compression)
    • Long-term mechanical behavior
    • Dimensional characteristics
    • Mechanical characteristics (ring stiffness, creep)
    • Impact
    • Slot / perforation widths
  • Storage of water and rainwater infiltration (boxes)

    • MFR (if PP or PE)
    • VICAT (if PVC)
    • OIT (if PP or PE)
    • Density
    • Tensile
    • Dimensional characteristics
    • Determination of the resistance in simple compression (vertical direction) on a basic modulus
    • Determination of the long-term compressive strength (vertical direction and horizontal direction)
  • Storage of water and rainwater infiltration (Thermoplastic tunnels)

    • MFR
    • OIT
    • Density
    • Tensile or flexion
    • Creep
    • Dimensional characteristics
    • Determination of arch stiffness
  • Network rehabilitation

    • Material characteristics
    • Dimensional characteristics
    • Short-term flexion
    • Long-term flexion
    • Tensile
  • Vacuum sewerage networks

    • Tightness of the element and the assembly
  • Pipes, piping systems and accessories (Pipes made of thermoplastic materials)

    • Internal pressure (pipes and fittings )
    • OIT (if PP or PE) / Vicat (if PVC) / MFR (if PP or PE) (pipes and fittings )
    • Tensile (Pipes)
    • Density (Pipes)
    • Ring flexibility (Pipes)
    • Impact resistance (pipes and fittings)
    • Ring stiffness (Pipes)
    • Heat reversion (Pipes)
    • Dimensional characteristics (pipes and fittings)
    • Tightness (pipes and fittings)
    • Creep ratio (Pipes)
    • Quality of elastomer sealing rings (pipes and fittings)
    • Mechanical resistance or flexibility of hand made fittings (Fittings)
  • Pipes, piping systems and accessories (GRP piping systems)

    • Material characteristics
    • Ring stiffness and initial tensile strength under flexing conditions
    • Tightness
    • Dimensional characteristics
  • Pipes, piping systems and accessories (Concrete pipes)

    • Dimensional characteristics
    • Mechanical resistance
    • Tightness
  • Pipes, piping systems and accessories (Case of sleeves)

    • Long-term shear strength
    • Tightness
    • Resistance to cycles at high temperatures (according to ATec requirements)
    • Dimensional characteristics
  • Pipes, piping systems and accessories (Branching saddles)

    • Vicat
    • Density
    • Internal pressure
    • Flexibility
    • Tightness
    • Quality of elastomer sealing rings
    • Dimensional characteristics
  • Pipes, piping systems and accessories (water meters)

    • MFR
    • Tensile
    • Density
    • weight
    • Mechanical resistance of the cover
    • Dimensional characteristics

Families


Documentation

Date Name Type Format
2021-05-01 Fascicule 70-1 - Fourniture, pose et réhabilitation de canalisations d'eaux à écoulement à surface libre Other PDF
2023-12-22 Referentiel-certification-QB09-rev12 Referential PDF
2023-12-22 Referentiel-certification-QB09-rev12-Annexe-Administrative Explicatif PDF
2023-12-22 DT 99009-2-6-Tubes-canalisations-accessoires-PRV-assainissement-gravitaire Other PDF
2021-09-02 DT 99009-1-1 - Réseaux de drains Other PDF
2021-09-02 DT 99009-1- 2 - Dispositifs d’assainissement non collectif Other PDF
2021-09-02 DT 99009-1-3 - Traitement des eaux pluviales Other PDF
2021-09-02 DT 99009-1-4 Dispositifs de stockage d’eau Other PDF
2021-09-02 DT 99009-2-1 - Réseaux de drains Other PDF
2022-03-09 DT 99009-2-2 - Tubes, canalisations et accessoires Other PDF
2021-09-02 DT 99009-2-3 Système pour assainissement pluvial Other PDF
2021-09-02 DT 99009-2-4 Réhabilitation de réseaux Other PDF
2021-09-02 DT 99009-2-5 Réseaux d’assainissement sous vide Other PDF
2023-11-10 Addendum applicable to all reference systems managed by CSTB Referential PDF

Comité particulier

Date Name Format
2020-05-15 Charte des membres de comités PDF
2023-03-30 Liste des membres du Comité QB 09 - Mars 2023 PDF
2020-09-01 Candidature pour un poste de membre de comité PDF